- PRIMOS III
PRIMOS III
Files:
Datasheet: | Download |
Description:
PRIMOS III is a high power and high efficiency surface mounted LED luminaire, designed for emergency lighting. Its main task is to illuminate escape routes, evacuation signs, rooms in public facilities, work places, etc.A high luminous flux makes it possible to use PRIMOS III at great heights.
PRIMOS II luminaire is compatible with all emergency lighting systems offered by HYBRYD.
LUMINAIRE FEATURES
• Deep discharge battery protection• Li-Ion batteries
• Possibility of connecting to the monitoring
system or collective power supply system
• Non-maintained or switched maintained operation mode
• Night operation and fire mode available for the CT version
• Lighting of escape routes, open spaces and fire points
• Adapted to high altitudes
• Housing is made of plastic
• Many light source supply power
• Wide range of optics
• Possibility to mounting outside the building
with additional mounting types
AVAILABLE SYSTEMS
STANDARD – tests commissioned manuallyAUTOTEST – internal components, battery and light source tests being performed automatically
CENTRALTEST – internal components, battery and light source tests being performed on command from the main unit of central management system
CB – luminaire supplied from HVCBS (230V AC / 216V DC / 108V DC), without address module
CBAM – luminaire supplied from the HVCBS (230V AC / 216V DC), with built-in address module
LVAM – luminaire supplied with 24V DC from the LVDBS system, with built-in address module
AVAILABLE OPTICS
AREA – (AR) symmetrical light distribution in all directions, recommended for use in places of considerable height or to illuminate fire pointsAREA PLUS – (AP) symmetrical light distribution in all directions, ensuring adequate illumination on a large area
LD – LED strip, symmetrical light distribution, transparent lampshade
CLA – LED strip with an opal shade, characterized by a low glare factor, symmetrical light distribution
ROAD – (RO) symmetrical light distribution in all directions ensuring adequate illumination on a large area
ROAD PLUS – (RP) light distribution mainly along the escape route with a much greater range than for the ROAD optics, for small heights
ROAD PLUS H/V – (RPHV) used to illuminate escape routes at the point of their intersections
MATERIAL
Housing material – PC/ABS mixHousing colour – RAL 9016, RAL 7042, RAL 7016, RAL 9005, other on special order
Lamp shade material – PC
Technical data:
Supply voltage | ST, AT, CT | 230V AC 50/60Hz |
---|---|---|
CB, CBAM | 230V AC 50/60Hz170–275V DC | |
LVAM | 24–48V DC | |
Protection class | ST, AT, CT, CB, CBAM | II |
LVAM | III | |
Ingress protection | IP65 | |
Light source | LED strip, LED modules1) | |
Light source lifespan | > 50 000h | |
Light colour temperature | CW | 5200–5700K |
NW | 3700–4200K | |
WW | 2700–3300K | |
Colour rendering index | 70 | |
Light source supply power | 2W, 3W, 5W, 7W, 10W | |
Minimum luminous flux | AR | 317lm, 460lm, 745lm, 942lm, 1274lm |
AP | 323lm, 465lm, 758lm, 954lm, 1259lm | |
RO | 311lm, 449lm, 742lm, 936lm, 1266lm | |
RP | 282lm, 407lm, 715lm, 870lm, 1148lm | |
RPHV | 291lm, 421lm, 716lm, 897lm, 1208lm | |
LD | 341lm, 485lm | |
CLA | 261lm, 370lm | |
Battery type and voltage | Li-Ion 7.4V | |
Battery capacity | 0.7, 2.2, 4.4Ah | |
Battery recharging time | ST, AT, CT | < 12h |
Emergency operation time | ST, AT, CT | 1h, 3h, 8h |
Ambient temperature | ST, AT, CT | +5 – +35˚C;TE:2) -20 – +35˚C |
CB, CBAM, LVAM | -10 – +45˚C;TE:2) -25 – +50˚C | |
Supply cable cross-section area | 0.5–2.5mm2 | |
Supply cable diameter | ≤ 13mm | |
Communication cable diameter | CT | ≤ 7mm |
Through wiring | ✓ | |
Suitable for surface wiring | ✓ |