1. Main
  2. Products
  3. Emergency Lighting Luminaires
  4. PRIMOS II

PRIMOS II

CNBOPPZH
Emergency Lighting Luminaire PRIMOS II
Emergency Lighting Luminaire PRIMOS II Emergency Lighting Luminaire PRIMOS II Emergency Lighting Luminaire PRIMOS II

Files:

Datasheet: Download
Manual: Download (ST AT CT)
Download (CB CBAM LV LVAM)
CNBOP: Download
Photometric data: Download
Hygienic certificate: Download

Description:

PRIMOS II is a high power and high efficiency surface mounted LED luminaire, designed for emergency lighting. Its main task is to illuminate escape routes, evacuation signs, rooms in public facilities, work places, etc.
A high luminous flux makes it possible to use PRIMOS II up to a height of 14 metres.
PRIMOS II luminaire is compatible with all emergency lighting systems offered by HYBRYD.

FEATURES:

• Deep discharge battery protection
• Non-maintained, switched maintained or night operation mode
• Possibility of connecting to the monitoring system or collective power supply system
• Lighting of escape routes, open spaces and fire points
• Adapted to high altitudes
• Housing is made of plastic
• Two light source supply power (5W/7W)
• Wide range of optics
• Possibility to mounting outside the building with additional mounting types C114, W221 or W22

AVAILABLE SYSTEMS:

ST, AT, CT, CB, CBAM, LVAM

MATERIAL:

Housing material – PC/ABS mix
Housing colours – RAL 9016, RAL 9005, other on special order
Lamp shade material – PC

Technical data:

Supply voltageAT, CT230V AC 50/60Hz
CB230V AC 50/60Hz 80–275V DC
CBAM230V AC 50/60Hz 170–275V DC
LVAM10–32V DC
Protection classST, AT, CT, CB, CBAMII
LVAMIII
Ingress protectionIP65
Light sourceLED Modules 1)
Light colour temperature5700K
Light source supply power5W, 7W
Minimum luminous flux (5W/7W)RO553/647 lm
RP547/640 lm
RPHV553/647 lm
AR535/626 lm
AP553/647 lm
Light source lifespan> 50 000h
Battery type / napięcieNi-Cd4,8V
Ni-MH8,4V
Battery capacity1,0; 1,5; 1,6; 2,1; 2,5; 4,0Ah
Battery charging time< 24h
Emergency operation time1h, 3h
Ambient temperature (5W/7W)ST, AT, CT+5 – +35˚C;
TE:2) -20 – +35˚C
CB, CBAM, LVAM-10 – +45˚C;
TE:2) -25 – +50˚C
Supply cable cross-section area0,5 – 2,5mm2
Supply cable diameter≤ 13mm
Communication cable diameter≤ 7mm
Suitable for through wiringYES
Suitable for surface wiringYES
1) Non-exchangeable, but serviceable light source