Legend

Available systems:

AT - AUTOTEST, automatic test execution
TS - TESTSYSTEM, automatic test execution and remote control
ST - STANDARD, manual testing
CT - CENTRALTEST, central monitoring system
CB - CENTRAL BATTERY

Tests

Test A - monthly executed functionality test
Test B - annually executed emergency supply test (emergency work time measurement test)

Work modes:

Basic work - 230V power supply
Emergency work - accumulator power supply
Work modes switching: basic/emergency mode is switched automatically
J - maintained, works in basic and emergency mode
C - non-maintained, works only in emergency mode
MS - mixed, two lamps work in basic mode, one lamp works in emergency mode
N - night, only for Centraltest. Works like in maintained version. Basic work time can be programmed with the use of the central unit
S - special

Other functions

Blockade - emergency work blockade activated or deactivated by terminals positioning
Sleep mode - emergency work blockade for the time of power supply failure. This blockade is released automatically once the power supply is provided

Mounting

W - mounted to wall
C - mounted to ceiling

Other abbreviations

DW - two-sided

PRYMAT STANDARD


CASING:

Body material: Plastic
Casing colour: White
Lamp cover shape: Flat
Oval
Two-sided
Lamp cover colour: Frosted
Transparent

TECHNICAL DATA:

Power supply: 230V AC/50Hz
Power consumption: <12W for fluorescent lamp,
<4W for LED
Protection class: II
Radio noise: Level N
Protection degree: IP53
Recharging time: 24h
Emergency work time: 1h, 2h or 3h
Light source: TL8W- G5 lamp or
White LED 1W
Accumulator type: NiCd HT
Accumulator lifespan: 4 years (suggested replacement after 4 years)
Ambient temperature: 0°C÷50°C
Connection block: For cables1,5mm2
Blockade: Yes

VERSIONS:

Luminaire nameWork modeTimeAccumulatorWeightCode
PRYMAT ST 3JMaintained3h2,4V/4,0Ah1,2 kg1066
PRYMAT ST 2JMaintained2h2,4V/2,5Ah1,1 kg1073
PRYMAT ST 1JMaintained1h2,4V/1,5Ah1,0 kg1080
PRYMAT ST 3CNon-maintained3h2,4V/4,0Ah1,1 kg1097
PRYMAT ST 2CNon-maintained2h2,4V/2,5Ah1,0 kg1103
PRYMAT ST 1CNon-maintained1h2,4V/1,5Ah0,9 kg1110
PRYMAT ST 3C2Non-maintained3h3,6V/4,0Ah1219
PRYMAT ST 2C2Non-maintained2h3,6V/2,5Ah1226
PRYMAT ST 1C2Non-maintained1h3,6V/1,5Ah1233
PRYMAT ST J LEDMaintained3h-1240
PRYMAT ST C LEDNon-maintained3h-1271
PRYMAT DW ST 3JMaintained3h2,4V/4,0Ah1127
PRYMAT DW ST 2JMaintained2h2,4V/2,5Ah1134
PRYMAT DW ST 1JMaintained1h2,4V/1,5Ah1141
PRYMAT DW ST 3CNon-maintained3h2,4V/4,0Ah1158
PRYMAT DW ST 2CNon-maintained2h2,4V/2,5Ah1165
PRYMAT DW ST 1CNon-maintained1h2,4V/1,5Ah1172
PRYMAT DW ST J LEDMaintained3h-8683
PRYMAT DW ST C LEDNon-maintained3h-8690

PICTOGRAMS:

Pictogram P01
P01
Pictogram P02
P02
Pictogram P03
P03
Pictogram P04
P04
Pictogram P05
P05
Pictogram P06
P06
Pictogram P07
P07
Pictogram P08
P08
Pictogram P09
P09
Pictogram P10
P10
Pictogram P11
P11
Pictogram P12
P12
Pictogram P13
P13
Pictogram P14
P14
Pictogram P15
P15
Pictogram P16
P16
Pictogram P17
P17
Pictogram P18
P18
Pictogram P19
P19
Pictogram P20
P20
Pictogram P21
P21
Pictogram P22
P22
Pictogram P23
P23
Pictogram P24
P24
Pictogram P25
P25
Pictogram P26
P26
Pictogram P27
P27

MOUNTING TYPES:

Mounting type C19
C19
Mounting type C20
C20
Mounting type C21
C21
Mounting type C22
C22
Mounting type W13
W13

ORDERING:

While ordering, the following shall be given:
- product code or luminaire name with pictogram code and mounting type, for example: 1066 P19 W13 or PRYMAT ST 3J P19 W13
- luminares quantity

CIRCUIT DIAGRAMS:

Circuit diagram PRYMAT STANDARD

DIMENSIONS:

Casing PRYMAT STANDARD Casing PRYMAT STANDARD