Legend

Available systems:

AT - AUTOTEST, automatic test execution
TS - TESTSYSTEM, automatic test execution and remote control
ST - STANDARD, manual testing
CT - CENTRALTEST, central monitoring system
CB - CENTRAL BATTERY

Tests

Test A - monthly executed functionality test
Test B - annually executed emergency supply test (emergency work time measurement test)

Work modes:

Basic work - 230V power supply
Emergency work - accumulator power supply
Work modes switching: basic/emergency mode is switched automatically
J - maintained, works in basic and emergency mode
C - non-maintained, works only in emergency mode
MS - mixed, two lamps work in basic mode, one lamp works in emergency mode
N - night, only for Centraltest. Works like in maintained version. Basic work time can be programmed with the use of the central unit
S - special

Other functions

Blockade - emergency work blockade activated or deactivated by terminals positioning
Sleep mode - emergency work blockade for the time of power supply failure. This blockade is released automatically once the power supply is provided

Mounting

W - mounted to wall
C - mounted to ceiling

Other abbreviations

DW - two-sided

ALU AUTOTEST


CASING:

Body material: Aluminium
Casing colour: White – RAL 9003, other colours available
Lamp cover material: Plexiglas
Shape: Plexiglas with pictogram
Lamp cover colour: Frosted

TECHNICAL DATA:

Power supply: 230V AC/50Hz
Power consumption: <12W for TL8W or
<4W for ALU AT LED
Protection class: I
Radio noise: Level N
Protection degree: IP40
Recharging time: 24h
Emergency work time: 1h, 2h or 3h
Light source: TL8W- G5 lamp or
White LED 1W
Accumulator type: NiCd HT
Accumulator lifespan: 4 years (suggested replacement after 4 years)
Ambient temperature: 0°C÷50°C
Connection block: 3x2,5mm2 or 4x2,5mm2
Blockade: Yes

VERSIONS:

Luminaire nameWork modeTimeAccumulatorWeightCode
ALU AT 3JMaintained3h3,6V/4Ah2926
ALU AT 2JMaintained2h3,6V/2,5Ah2933
ALU AT 1JMaintained1h3,6V/1,5Ah2940
ALU AT 3CNon-maintained3h3,6V/4Ah2988
ALU AT 2CNon-maintained2h3,6V/2,5Ah2995
ALU AT 1CNon-maintained1h3,6V/1,5Ah3008
ALU AT J LEDMaintained3h4,8V/1,0Ah3633
ALU AT C LEDNon-maintained3h4,8V/1,0Ah3664
ALU D AT 3JMaintained3h3,6V/4Ah2957
ALU D AT 2JMaintained2h3,6V/2,5Ah2964
ALU D AT 1JMaintained1h3,6V/1,5Ah2971
ALU D AT 3CNon-maintained3h3,6V/4Ah3015
ALU D AT 2CNon-maintained2h3,6V/2,5Ah3022
ALU D AT 1CNon-maintained1h3,6V/1,5Ah3039
ALU D AT J LEDMaintained3h4,8V/1,0Ah3695
ALU D AT C LEDNon-maintained3h4,8V/1,0Ah3725
ALU DW AT 3JMaintained3h3,6V/4Ah0007
ALU DW AT 2JMaintained2h3,6V/2,5Ah0014
ALU DW AT 1JMaintained1h3,6V/1,5Ah0021
ALU DW AT 3CNon-maintained3h3,6V/4Ah0038
ALU DW AT 2CNon-maintained2h3,6V/2,5Ah0045
ALU DW AT 1CNon-maintained1h3,6V/1,5Ah0052
ALU DW AT J LEDMaintained3h4,8V/1,0Ah0069
ALU DW AT C LEDNon-maintained3h4,8V/1,0Ah0076
ALU D DW AT 3JMaintained3h3,6V/4Ah0083
ALU D DW AT 2JMaintained2h3,6V/2,5Ah0090
ALU D DW AT 1JMaintained1h3,6V/1,5Ah0106
ALU D DW AT 3CNon-maintained3h3,6V/4Ah0113
ALU D DW AT 2CNon-maintained2h3,6V/2,5Ah0120
ALU D DW AT 1CNon-maintained1h3,6V/1,5Ah0137
ALU D DW AT J LEDMaintained3h4,8V/1,0Ah0144
ALU D DW AT C LEDNon-maintained3h4,8V/1,0Ah0151

PICTOGRAMS:

Pictogram P01
P01
Pictogram P02
P02
Pictogram P03
P03
Pictogram P04
P04
Pictogram P05
P05
Pictogram P06
P06
Pictogram P07
P07
Pictogram P08
P08
Pictogram P09
P09
Pictogram P10
P10
Pictogram P11
P11
Pictogram P12
P12
Pictogram P13
P13
Pictogram P14
P14
Pictogram P15
P15
Pictogram P16
P16
Pictogram P17
P17
Pictogram P18
P18
Pictogram P19
P19
Pictogram P20
P20
Pictogram P21
P21
Pictogram P22
P22
Pictogram P23
P23
Pictogram P24
P24
Pictogram P25
P25
Pictogram P26
P26
Pictogram P27
P27

MOUNTING TYPES:

Mounting type C1
C1
Mounting type C2
C2
Mounting type C3(DW)
C3(DW)
Mounting type C4(DW)
C4(DW)
Mounting type W1
W1
Mounting type W2
W2

ORDERING:

While ordering, the following shall be given:
- product code or luminaire name with pictogram code and mounting type, for example: 2926 P19 W2 or ALU AT 3J P19 W2
- luminares quantity

Photo ALU AUTOTEST Photo ALU AUTOTEST

CIRCUIT DIAGRAMS:

Circuit diagram ALU AUTOTEST

DIMENSIONS: